GROUNDING TRANSFORMER SPECIFICATION SHEET

*Required Fields

Contact Name

Email

Phone No

State

Zip Code

Company Name

City

Customer PO#

SO#

SE

FLUID

      SILICON
      BIOTEMP
     ENVIROTEMP(FR3)
     VOLT ESSO
     TYPE II OIL

QTY

TEMP

     55 C
     65 C
     55 C - 65 C
     OTHER
         

PHASE

     THREE
     SINGLE
     GROUNDING
     RECTIFIER
         

PART#

COOLING

     ONAN
     ONAN / ONAF-FFA
     ONAN / ONAF-less fans
     ONAN / ONAF

KVA

HERTZ

     50 hz
     60 hz

CONDUCTOR

     Aluminium
     Copper

AMBIENT:

     30 C avg.
     40 C avg.
     Other
         
     5 LEGGED CORE
     TERTIARY
     TRIPLEX CORE/COIL

CATALOG #

 

HIGH VOLTAGE

     HV 
         BIL:(in kV) 

TAPS:

     2-2 1/2% FCAN & BN
     4-2 1/2% FCBN
     2-2 1/2% FCAN & 4-2 1/2% FCBN
     OTHER
         
     ES SHIELD
     BALANCED TAPS
     WET WIND

LOW VOLTAGE

     LV 
         BIL:(in kV) 

HV CONNECTION

     DELTA
     WYE
         HO Bushing w/full BIL
             HO Ground Strap
         Neutral internal & isolated
         Neutral internally grounded
     GROUNDED WYE (HO-XO Comm.)
     DELTA WYE
     ZIG ZAG

IMPEDENCE

     MIN
     NOM
     MAX
     

LV CONNECTION

     DELTA
         With single Phase Mid-Tap Coil
     WYE
         XO bushing
          XO bushing w/ground strap
     GROUNDED WYE (XO-HO Comm.)
     DELTA WYE
     ZIG ZAG

VECTOR CONNECTION

     
 

HV CONFIGURATION

     Radial Feed
     Loop feed
     Dual Radial feed (Alternate Source)
     6 Bushings (RADIAL FEED)
        3 for incoming feeders
        3 for arresters

HV BUSHINGS

     Live Front
         5/8" eyebolt
         2-hole G spade
         OTHER
             
         Cable Supports
     Dead Front
         Wells

INSERTS FACTORY INSTALLED

     Inserts
         QTY 
     Feed thru
         QTY 
     One Pc. 200A LB
     One Pc. 600A Deadbreak
     Other
         
     Cable Supports

LV BUSHINGS:

     4-hole spade
     6-hole spade
     8-hole spade
     10-hole spade
     12-hole spade
     OTHER
         
     Standard
     Bushing Supports
     Lugs
         
 
Next >>

ACCESSORIES:

     Standard (L. L. Gauge, Thermometer, P.V. Gauge, 1" fill plug & filter press connect., 1" DV&S, pressure relief valve, NON-PCB on Nameplate,gas sample valve, Pentahead Locking Device (unless noted otherwise).) [P.V. Bleeder supplied on power class units 75

GAUGES & PRESSURE DEVICES

     Thermometer w/2 contacts **
     Liquid level gauge w/contact **
     Pressure-vacuum gauge w/contacts **
     Bleeder Valve
     Sudden Pressure relay
     Seal in relay
         AC
         DC
     Pressure relief device
         with contacts
     Winding temp therm w/2 cont.
     OTHER
         

TANK FITTINGS

     2" DV&S (std above 2500 kva)
     1" fill valve (std above 2500 kva)
     Bolted tank cover
     Hexhead locking device
     Key Interlock *
         
         Provisions ONLY
     Phase Barriers
         HV
         LV
     Front Barriers
         HV
         LV

FUSES

     Internal weak link
     Bay-o-net
         Dual Sensing
         High Current
         Fault Sensing
         Partial Range ELSP CL back-up
     ELS BON (current limiting)
     Under oil current limiting
     Drywell canisters
         Non-loadbreak - INTERLOCKED
         Loadbreak
     NX clip style
     Arc strangler fused switch
     Spares
         QTY 
     OTHER

MISC

     Seismic Anchoring Pads
     Danger signs
         QTY 
     OTHER
         
 

SECONDARY METERING & PROTECTION

     KWH Meter
         type 
     Socket only
         type 
     CT Ratio
         
     PT Ratio
         
     M/C Breaker; Dim & type
         
         Supplied by others-Manufacturer installed
         Mounting provisions only

SWITCHES

     Dual radial (A/Open/B/Open)
     Loop feed "V" blade
     Loop feed "T" blade
     Arc-strangler disconnect
     Dual voltage switch
     Delta-Wye switch
     Switch Interlocked w/fuse holders
     On-Off (2 positions)
         QTY 

ARRESTERS

     Dead front M.O.V.E.
         (kv) 
     Internal under oil
         (kv) 
     Live front arresters
         Distribution Class
             (kv) 
         Intermediate Class
             (kv) 
         Station Class
             (kv) 
 

PAINT: (Standard finish is industrial enamel)

     Padmount Green
     ASA 24
         ASA61
     ASA49
         ASA70
     Touch-up
     UNDERCOAT
     EPOXY
         Primer only
     OTHER
         
     EXACT DUPLICATE to:
         
     SIMILAR to:
         
         Maintain Dimensions
         Exceptions:  
     DRAWING/PHOTOS attached
     Special Dimensions

   Manufacturer's ID Plate

   Customer ID Plate

   UL Label Required

SPECIAL ITEMS & SPECIFICATIONS (see also spec sheet #2)

     

SPECIAL REQUIREMENTS SPECIFICATION SHEET

     Customer 
     Customer PO# 
     SE: 
     CATALOG # 
     KVA: 
     QTY: 
     SO# 
     PART# 
 
<< Previous   Next >>

STAINLESS STEEL

     HARDWARE (nuts, bolts, studs, washers)
     TANK (plug, weld flanges, lift lugs, rectangular handhole, braces, PRD ring, nipples for fill and drain, studs not included)
         Padmount (parking stands, jack lugs, rectangular handhole cover, PRD ring, PRD cover)
     TRANSITIONS
     BASE
     COMPARTMENT
     RADIATORS (SS valve not available)
     Fill / Drain Valve without sampler
 

RADIATORS

     REMOVABLE RADIATORS
         Shipped Installed
         Shipped Separately
            NOTE: Engineering decides if fluid ships in tank or barrels (indicated on construction note)
 

MISCELLANEOUS ITEMS

     Containment Pan
     Explosion Proof Wiring Box
         Classification 
            Voltage
                 120V
                 240V
             # of Safepaks  

SPECIAL TRANSITION SIZES

    DRAWING/PHOTOS
     attached
     Special Dimensions
         
 
<< Previous   Next >>

CUSTOMER SPECIAL REQUIREMENTS

     Witness Testing
     Final Inspection
     ANSI Full Series Impulse Test
     ANSI Sound Level Test
     ANSI Temperature Test
     OTHER
         

SPECIAL SHIPPING REQUIREMENTS

     Pallet
         
     Crate
         
     Shipping Cover
     Impact Indicator
     Customer Supplied
         
     Other
         
 

Notes

 