Pacific Crest Grounding transformers are used to provide a ground path to either an ungrounded "Y" or a delta connected system and are used to.....

  • Provide a relatively low impedance path to ground, thereby maintaining the system neutral at or near ground potential.
  • Limit the magnitude of transient over voltages when re-striking ground faults occur.
  • Provide a source of ground fault current during line to ground faults.
  • Permit the connection of secondary loads if desired.

All ratings are designed in accordance with applicable ANSI, NEMA and IEEE standards.



Liquid-filled Transformers Grounding type 480 volts to 46 kV


Ratings

  • Primary Voltage - all voltages through 46 kV - 250 kV BIL
  • Secondary Voltage - all voltages through 15 kV
  • Frequency - 60Hz
  • Temperature rise 65° C
  • Consult factory for ratings not shown

Standard Features

  • Secondary spade connectors when required
  • Primary clamp type eyebolt connectors
  • Combination drain and sampler (750 kVA and above)
  • Pressure test and upper filter press connection - 1" pipe plug
  • NEMA two hole ground pad
  • Corrosion resistant nameplate
  • Provisions for jacking and lifting
  • Base suitable for rolling or skidding
  • Pressure relief valve
  • Rugged steel plate tank reinforced with steel channel selections for strength and rigidity
  • Undercoated base
  • Door has three-point locking mechanism
  • Externally clamped bushings
  • When secondary bushings are provided, primary compartment accessible only after low voltage door is opened
  • 1/2" liquid level plug
  • Welded cover with handhole

Optional Features

  • Five-legged core for wye-wye connections
  • 50 cycle
  • 55/65° C temperature rise
  • High fire point liquid
  • Loop feed construction
  • Dead front construction
  • Lightning arrestors
  • Dial type thermometer
  • Liquid level gauge
  • Pressure vacuum gauge
  • Pressure vacuum bleeder
  • Combination drain and sampler
  • Pressure relief device
  • Bay-o-net fuses
  • Weak links
  • Current limiting fuses
  • Loadbreak oil switch(es)
  • Primary current transformers
  • Gauges furnished with alarm contacts
  • Bolted cover with handhole
  • Zig-zag designs

Standard Tests

Each unit is subjected to the following tests:

  • Resistance
  • Ratio
  • Polarity
  • Phase relation
  • Core loss
  • Exciting current
  • Impedance
  • Load loss
  • Applied potential test
  • Induced potential test
  • Quality control impulse test
  • Pressure leak test